Model
|
Boaray 600D
|
Boaray 600C
|
|
Dimensions and weight
|
Main unit: 1385 mm (H) × 850 mm (W) × 633 mm (D), 80 kg (without vaporizer and cylinder)
|
|
Top shelf: 535 mm (W) × 382 mm (D), limit 34 kg
|
|
Drawer: 150 mm (H) × 338 mm (W) × 308 mm (D)
(internal size), quantity: standard 2
|
Drawer: 150 mm (H) × 338 mm (W) × 308 mm (D)
(internal size), quantity: standard 1, optional 2
|
|
Caster: 100 mm, two front casters with brakes
|
|
Ventilation mode
|
VCV, PCV, SIMV(V)+PS, SIMV(P)+PS, Manual, Standby
CPAP / PSV (optional)
|
VCV, PCV, Manual, Standby
|
|
Compensation
|
Circuit gas leakage compensation and automatic compliance compensation
|
|
Ventilation parameters
|
Patient type: adult, pediatric, infant
|
|
Tidal volume:
(pediatric / infant) 20 ~ 300 ml, (adult) 100 ~ 1500 ml
(increments of 5 ml)
|
Tidal volume:
(pediatric / infant) 40 ~ 300 ml, (adult) 100 ~ 1500 ml
(increments of 5 ml)
|
|
Pinsp: 5 ~ 70 cmH₂O (increments of 1 cmH₂O)
|
|
Plimit: (PEEP + 5) ~ 70 cmH₂O (increments of 1 cmH₂O)
|
|
Freq in SIMV mode: 1 ~ 40 bpm, others mode: 4 ~ 60 bpm
(increments of 1 bpm)
|
|
I : E: 3 : 1 ~ 1 : 6 (increments of 0.5)
|
|
Tpause: OFF, 5 % ~ 50 % (increments of 5 %)
|
|
Ti: 0.1 ~ 10.0 s (increments of 0.1 s)
|
|
Flow trigger: 1 ~ 15 L/min (increments of 1 L/min)
|
|
Psupp: 5 ~ 60 cmH₂O (increments of 1 cmH₂O)
|
|
Positive end expiratory pressure
(PEEP)
|
Type: integrated, electronic controlled
|
/
|
|
PEEP: OFF, 4 ~ 20 cmH₂O (increments of 1 cmH₂O)
|
|
Ventilator performance
|
Driving pressure: 280 kPa to 600 kPa
|
|
Peak gas flow: 120 L/min + fresh gas flow
|
|
Monitoring parameters
|
Minute volume: 0 ~ 60 L/min
|
|
Tidal volume: 0 ~ 2000 ml
|
|
FiO₂: 21 % ~ 100 %
|
|
Ppeak: 0 ~ 100 cmH₂O
|
|
Pmean: 0 ~ 100 cmH₂O
|
|
Pplate: 0 ~ 100 cmH₂O
|
|
I : E: 3 : 1 ~ 1 : 6
|
|
Rate: 0 ~ 100 bpm
|
|
PEEP: 0 ~ 70 cmH₂O
|
|
Resistance (R): 0 ~ 200 cmH₂O / (L/s)
|
|
Compliance (C): 0 ~ 200 ml/cmH₂O
|
|
Control accuracy
|
Volume delivery:
< 100 ml: ± 20 ml
≥ 100 ml: ± 20 ml or ± 15 % of the set value, whichever is greater
|
|
Pressure delivery: ± 2.0 cmH₂O or ± 10 % of the set value, whichever is greater
|
|
PEEP delivery: ± 2.0 cmH₂O or ± 10 % of the set value, whichever is greater
|
|
Monitoring accuracy
|
Volume monitoring:
< 100 ml: ± 20 ml
≥ 100 ml: ± 20 ml or ± 15 % of the reading, whichever is greater
|
|
Pressure monitoring: ± 2.0 cmH₂O or ± 10 % of the reading, whichever is greater
|
|
PEEP monitoring: ± 2.0 cmH₂O or ± 10 % of the reading, whichever is greater
|
|
Log
|
500 events storage, first in first out
|
|
Alarm settings
|
Tidal volume
High: 40 ~ 1500 ml, OFF
Low: OFF, 140 ~ 1500 ml
|
|
Minute volume
High: 1 ~ 40 L/min, OFF
Low: OFF, 1 ~ 40 L/min
|
|
Airway pressure
High: 1 ~ 100 cmH₂O
Low: 0 ~ 99 cmH₂O
|
|
Freq
High: 1 ~ 60 bpm, OFF
Low: 0 ~ 60 bpm
|
|
FiO₂
High: 21 ~ 100 %, OFF
Low: OFF, 18 ~ 99 %
|
FiO₂
High: OFF, 21 ~ 100 %
Low: 21 ~ 100 %, OFF
|
|
Apnea alarm: 10 ~ 40 s
|
|
Sustained airway pressure alarm: 15 s
|
|
Negative pressure alarm: Paw < - 10 cmH₂O
|
|
Alarm silence countdown timer: 120 to 0 seconds
|
|
System language
|
Chinese, English, Spanish, French, Portuguese
|
|
Flow sensor
|
Type: variable orifice flow sensor
|
|
Position: inspiratory and expiratory port
|
|
Oxygen sensor
|
Type: chemical
|
|
FiO₂ displayed: 21 % to 100 %
|
|
Accuracy: ± (volume fraction of 2.5 % + 2.5 % gas level)
|
|
Response time: ≤ 15 seconds
|
|
Ventilator screen
|
Display type: color TFT touch screen, integrated
|
|
Display size: 8.4 inch
|
|
Resolution: 800 × 600
|
|
Display parameter: all setting and alarm parameters
(including Frequency, I/E ratio,
Tidal volume, Minute volume, PEEP,
Pmean, Ppeak, Pplat, and FiO₂, EtCO₂)
|
Display parameter: all setting and alarm parameters
(including Breath rate, I/E ratio,
Tidal volume, Minute volume, PEEP, MEAN,
PEAK, PLAT, and O₂ concentration, EtCO₂)
|
|
Display waveform: P-T, F-T, V-T, CO₂-T (optional)
|
Display waveform: P-T, F-T, V-T
|
|
Loop:P-V, F-V and F-P
|
/
|
|
Timer: on screen timer
|
|
Communication port
|
RS-232C connector × 1
|
|
Vaporizer
|
Vaporizer brand: YAFMED anesthetic vaporizer or Penlon Sigma Delta anesthetic vaporizer
|
|
Support agent: Halothane, Enflurane, Isoflurane, Sevoflurane
|
|
Position: standard 1, optional 2
|
|
Mounting mode: Selectatec®, with interlocking function
|
|
Fill method: Key fill, Pour fill, Quick fill
|
|
Mainstream CO₂ module
(Masimo IRMA)
|
Displayed numeric: EtCO₂, FiCO₂
|
/
|
|
Measurement range: 0 ~ 99 mmHg
|
|
Accuracy: ± (0.3 vol % + 4 % of reading)
|
|
Waveform / loop: CO₂-time
|
|
EtCO₂ high alarm limits: 1 ~ 100 cmH₂O
|
|
EtCO₂ low alarm limits: 0 ~ 99 cmH₂O
|
|
Multi-gas module
(Masimo IRMA)
|
Measurement mode: main-stream
|
/
|
|
Monitor gas: monitor gases CO₂, N₂O, Halothane,
Enflurane, Isoflurane, Sevoflurane, Desflurane, MAC.
|
|
Warm-up time: < 20 sec
(concentrations are reported and the automatic
agent identification is running within 20 seconds)
|
|
Accuracy:
CO₂: ± (0.3 vol % + 4 % of reading)
N₂O: ± (2 vol % + 5 % of reading)
HAL, ENF, ISO, SEV, DES: ± (0.2 vol % + 10 % of reading)
|
|
Power and battery backup
|
Power input: 110 ~ 240 V AC, 50 / 60 Hz
|
|
Auxiliary electrical outlet: up to 3 outlets (1.5 A for each)
|
|
Battery backup: 60 min for backup battery
(powered by new fully-charged batteries with 25 ℃ ambient temperature)
|
|
Battery type: build-in Li-on battery, 11.1 VDC, 7800 mAh
|
|
Safety feature: in case of electricity and battery failure, manual ventilation,
gas delivery and agent delivery are possible
|
|
ACGO
(Auxiliary Common Gas Outlet)
|
Connector size: ISO 22 mm OD and 15 mm ID
|
|
Pipeline supply
|
Gas type: O₂, N₂O, Air
|
O₂ & N₂O or O₂ & Air
|
|
Pipeline input range: 280 to 600 kPa
|
|
Pipeline connection: NIST
|
|
Pipeline supply pressure gauge
|
Display type: mechanical
|
|
Range: 0 to 1 MPa
|
|
Accuracy: ± (4 % of the full scale reading + 8 % of the actual reading)
|
|
Cylinder supply
|
Cylinder type: E-size cylinder (US standard or UK standard)
|
|
O₂ input range: 400 to 450 MPa
|
|
N₂O input range: 400 to 450 MPa
|
|
Cylinder connection: Pin-Index Safety System (PISS)
|
|
Yoke configuration: O₂, N₂O
|
|
Cylinder supply pressure gauge
|
Display type: mechanical
|
|
O₂ range: 0 to 25 MPa
|
|
N₂O range: 0 to 25 MPa
|
|
Accuracy: ± (4 % of the full scale reading + 8 % of the actual reading)
|
|
O₂ control
|
Method: N₂O shut off with loss of O₂ pressure
|
|
O₂ flush: 25 ~ 75 L/min
|
|
O₂-N₂O link system
|
Type: mechanical
|
|
Range: O₂ concentration not lower than 21 %
|
|
Auxiliary O₂ flowmeter
|
Range: 0 ~ 15 L/min
|
/
|
|
Indicator: flow tube
|
|
Mechanical control flow meter
|
O₂ flow range: two flow tubes with the range of 0 ~ 1 L/min and 1 ~ 10 L/min
|
|
N₂O flow range: two flow tubes with the range of 0 ~ 1 L/min and 1 ~ 10 L/min
|
|
Air flow range (optional): one flow tube with
the ranges of 1 ~ 10 L/min
|
Air flow range: two flow tubes with the range of
0 ~ 1 L/min and 1 ~ 10 L/min
|
|
Accuracy: ± 10 % of the indicated value (flow between 10 % and 100 % of full scale)
± 200 ml/min (for the flow under 10 % of the full scale)
|
|
Operating environment
|
Temperature: 10 ~ 40 ℃
|
|
Relative humidity (non-condensing): 15 % ~ 95 % R.H.
|
|
Atmospheric pressure: 70 ~ 106 kPa
|
|
Storage and transport environment
|
Temperature: - 20 ~ 55 ℃
|
|
Relative humidity (non-condensing): 10 % ~ 93 % R.H.
|
|
Atmospheric pressure: 50 ~ 106 kPa
|
|
Electromagnetic compatibility
|
Immunity: complies with all requirements of IEC 60601-1-2
|
|
Emission: complies with all requirements of IEC 60601-1-2
|
|
Breathing system
|
Material: PC
|
|
CO₂ Absorber
|
Absorbent capacity: 1500 ml
|
|
Breathing circuit parameters
|
Compliance: 0.87 ml/100Pa (bag mode)
Automatically compensates for compression losses within the breathing circuit in mechanical mode.
|
|
Expiration resistance: < 0.6 kPa @ 30 L/min
|
|
Inspiration resistance: < 0.6 kPa @ 30 L/min
|
|
System pressure gauge
|
Range: - 20 ~ 100 cmH₂O
|
|
Accuracy: ± (2 % of the full scale reading + 5 % of the actual reading)
|
|
Ports and connector
|
Exhalation, Inhalation, Manual bag port: 22 mm OD / 15 mm ID conical
|
|
APL valve
|
Range: 2 ~ 70 cmH₂O
|
|
Tactile knob indication at above 30 cmH₂O.
|
|
Accuracy: ± 10 cmH₂O or ± 15 % of the setting value, which is greater
|
|
Anesthetic Gas Scavenging System
(AGSS)
|
Size: 480 mm (H) × 134 mm (W) × 95 mm (D)
|
|
Type of disposal system: low flow active AGSS
|
|
Applicable standard: ISO 80601-2-13
|
|
Pump rate: 40 ~ 50 L/min
|
|
Connector of the disposal system: ISO 9170-2
|